Update Koch getting_started example with firmware recovery steps

This commit is contained in:
Cole Harrison 2025-02-22 10:33:01 -06:00
parent 04ecb5bc0c
commit 5943c438d0
1 changed files with 3 additions and 2 deletions

View File

@ -249,8 +249,9 @@ Steps:
- Select the motors one by one and move the arm. Check that the graphical indicator near the top right shows the movement.
** There is a common issue with the Dynamixel XL430-W250 motors where the motors become undiscoverable after their upgrading their firmware from Mac and Windows Dynamixel Wizard2 applications. When this occurs, it is required to do a firmware recovery (Select `DYNAMIXEL Firmware Recovery` and follow the prompts). There are two known workarounds to conduct this firmware reset:
1) Install the Dynamixel Wizard on a linux machine and complete the firmware reset
2) Use the Dynamixel U2D2 in order to perform the reset. This U2D2 can be purchased [here](https://www.robotis.us/u2d2/).
1) Install the Dynamixel Wizard on a linux machine and complete the firmware recovery
2) Use the Dynamixel U2D2 in order to perform the reset with Windows or Mac. This U2D2 can be purchased [here](https://www.robotis.us/u2d2/).
For either solutions, and open DYNAMIXEL Wizard 2.0, select the appropriate port. You will likely be unable to see the motor in the GUI at this time. Select `Firmware Recovery`, carefully choose the correct model, and wait for the process to complete. Finally, re-scan to confirm the firmware recovery was successful.
**Read and Write with DynamixelMotorsBus**